Hurricane 130: Difference between revisions
(Added Davis-Besse NPP's old system of Hurricanes to the table. Image of one of the hurricanes to be added soon) |
(Added photo of one of Davis-Besse NPP's Hurricanes to the page) |
||
Line 9: | Line 9: | ||
The '''Hurricane''' was an Electromechanical siren manufactured by [[Alerting Communicators of America]]. It was an 8/10 port dual tone siren, meant to compete with [[Federal Signal]]'s [[Thunderbolt]] siren series at the time. Two known models were produced. First came the '''Hurricane 130''', which was a rectangular horned model that closely resembled Federal's Thunderbolt siren. Later on, A.C.A. opted to change the design of the Hurricane to make it stand out from the Thunderbolt and avoid potential lawsuits over the two similar designs. Aside from that, they decided to correct some design flaws that were discovered in the original model. These changes to the design include, pole mounted vertical blower, controller removed from blower assembly and housed in it's own cabinet, and most notably, the horn changed from rectangular to round. This model was dubbed the '''Hurricane 130 MKII''' by the company. In 1981, A.C.A. ceased production of the Hurricane in favor of the [[P-50]]. | The '''Hurricane''' was an Electromechanical siren manufactured by [[Alerting Communicators of America]]. It was an 8/10 port dual tone siren, meant to compete with [[Federal Signal]]'s [[Thunderbolt]] siren series at the time. Two known models were produced. First came the '''Hurricane 130''', which was a rectangular horned model that closely resembled Federal's Thunderbolt siren. Later on, A.C.A. opted to change the design of the Hurricane to make it stand out from the Thunderbolt and avoid potential lawsuits over the two similar designs. Aside from that, they decided to correct some design flaws that were discovered in the original model. These changes to the design include, pole mounted vertical blower, controller removed from blower assembly and housed in it's own cabinet, and most notably, the horn changed from rectangular to round. This model was dubbed the '''Hurricane 130 MKII''' by the company. In 1981, A.C.A. ceased production of the Hurricane in favor of the [[P-50]]. | ||
[[File:ACA Hurricane.jpg|thumbnail|A Hurricane two years before being removed in Garland, Texas]] | [[File:ACA Hurricane.jpg|thumbnail|A Hurricane two years before being removed in Garland, Texas]] | ||
==Cities using the Hurricane== | ==Cities using the Hurricane== | ||
{| class="wikitable" | {| class="wikitable" | ||
Line 72: | Line 73: | ||
| 130 MKII | | 130 MKII | ||
|} | |} | ||
[[File:Davis Besse Hurricane.jpg|thumbnail|A Hurricane at Davis-Besse Nuclear Power Plant in Oak Harbor, OH. The system of Hurricanes were replaced in the mid-late 1990's]] | |||
[https://www.youtube.com/watch?v=0nHaAzz8dDs Hurricane 130 MKII in Milwaukee, WI.] | [https://www.youtube.com/watch?v=0nHaAzz8dDs Hurricane 130 MKII in Milwaukee, WI.] |
Revision as of 13:44, 18 April 2019
Hurricane 130 | |
[[File:|200px]] | |
Company | Alerting Communicators of America |
---|---|
Produced | 1968-1981 |
Type | Electromechanical |
Sound output | 130 |
The Hurricane was an Electromechanical siren manufactured by Alerting Communicators of America. It was an 8/10 port dual tone siren, meant to compete with Federal Signal's Thunderbolt siren series at the time. Two known models were produced. First came the Hurricane 130, which was a rectangular horned model that closely resembled Federal's Thunderbolt siren. Later on, A.C.A. opted to change the design of the Hurricane to make it stand out from the Thunderbolt and avoid potential lawsuits over the two similar designs. Aside from that, they decided to correct some design flaws that were discovered in the original model. These changes to the design include, pole mounted vertical blower, controller removed from blower assembly and housed in it's own cabinet, and most notably, the horn changed from rectangular to round. This model was dubbed the Hurricane 130 MKII by the company. In 1981, A.C.A. ceased production of the Hurricane in favor of the P-50.
Cities using the Hurricane
Cities Using Or That Have Used The ACA Hurricane | Number of Sirens, Operation Status | Model |
---|---|---|
Addyston, OH | 1, Removed, in private possession | 130 MKII |
Baxter, MN | 1, Removed | 130 |
Normal, IL | 2 (Exact number unknown), Removed | 130 MKII |
Crystal River, FL | Approximately 10, Removed (Crystal River NPP system) | 130 MKII |
Centralia, IL | 1, Removed In 2010, Recently changed ownership into the hands of a collector in Michigan. | 130 |
Darien, IL | 2, 1 Still Operational, 1 Removed for Private Possession. | 130 MKII |
Fayetteville, OH | 1, Removed | 130 MKII |
Garland, TX | 4, Removed | 130 MKII |
Greendale, WI | 1, Removed | 130 MKII |
Greenville, TX | 2, most likely inactive | 130 MKII |
La Crescent, MN | 3, Removed (1 Hurricane was replaced by a Sentry siren and other Hurricane was replaced by a Federal Signal 2001-130) | 130 MKII |
Milwaukee, WI | 2, 1 operational. The other one is stored at the American Signal Corporation Headquarters. More were installed in the city at one time | 130 MKII |
Rolling Meadows, IL | 3, replaced in the 1980s with Alertronics | 130 |
Oak Harbor, OH | (Exact number unknown), Removed (Part of the Davis-Besse NPP System). Replaced with a system of 2001-SRN's in the mid-late 1990's | 130 MKII |