Southern California Edison Model 120: Difference between revisions

From airraidsirens.net, the Internet's premiere site for siren information and discussion
Jump to navigation Jump to search
No edit summary
(Moved page over from the CDS Wiki.)
(18 intermediate revisions by 3 users not shown)
Line 1: Line 1:
{{Infobox siren
{{Infobox siren
|image =[[File:Model 120.jpg|Unit installed on a wood pole]]
|image =Model 120.jpg  
|company= Southern California Edison
|company= Southern California Edison
|produced=September 1982 and 1988
|produced= 1982-1988
|type=[[Pneumatic]]  
|type=[[Supercharged]] [[Electromechanical]] [[Omnidirectional]] [[Pneumatic]]  
|output=120
|output=120 dB @ 100 ft
|hertz = 240 or 300  
|hertz = 240 or 300  
|neigh = 2 (Rotor) 10 (Blower)
|caption=A Model 120 unit on a Sentry mount.|hp=2 hp (chopper)
}}
10 hp (blower)}}
The Socal Edison (SCE) 120 or Model 120 was a SoCal Edison manufactured 120 dB siren which was designed by John Glenn Powell. He is a now retired sound engineer at the San Onofre Nuclear Generating Station located in San Clemente, California. There were 22 of these sirens produced with one being never installed which is now privately owned. 16 were installed in September 1982 to add into a system of 29 Federal Signal STL-10s that were installed in October 1981, and later in 1988 5 additional locations were installed. The reason these sirens were made is because there was no other siren available that would meet the plants needs. They did look into Cyclone 120s but they realized that they have massive 50 Hp motors and are 3 Phase (which the plant wanted to use 1 phase motors.) the other reason is because the STL-10s underperformed in all areas they were placed in ,as well as federal lied to them about the STL-10 being 120 decibels and carry 6,000+ feet. So starting in late 1981 ,Model 120 prototypes started to be made and tested with the final designed units being completed and the first 17 installed in September of 1982 and 4 in 1988. Originally the plan was to have all 50 sirens Model 120s Which means swapping out the existing 29 STL-10s with 120s ,but the plant decided just to keep the underperforming STL-10s and just add 21 Model 120s in areas that need more coverage. For around a decade, they were thought to be "Toshiba" sirens, because they were pneumatic and people just assumed they were made by Toshiba, who also made pneumatic sirens. The Model 120 is a Pneumatic siren, meaning it requires an external air source to produce sound. The sound is chopped by a rotor, which sits inside a hollow cylinder, or stator, which acts as a chamber to contain the air inside. 8 Small narrow slots on the stator allow the sound to come out. The sound is then projected by 8 large fiberglass horns. It consists of a belt driven Paxton blower, that uses a 10 Hp TEFC motor. The rotor is 9.75 inches in diameter and has 5 ports. Including the stator it is in total 11.75 inches in diameter. The rotor is powered by a 2 Hp TEFC motor that spins at 3600 RPM. After about 10-15 years of being exposed to salty air ,the Model 120s were starting to develop corrosion on their rotor and blower motors due to the motors being residential use motors instead of commercial use motors. Also ,they did not have corrosion resistant paint like ,motors on commercially produced sirens ,This lead to SONGS having some malfunctions as well as them sometimes failing to sound on routine maintenance and tests. By 6-10-2004, the plant was discussing the replacement process. Starting In November 2005 ,the Model 120s and the STL-10s were starting to be gradually removed and replaced ,and by Febuary 2006 all have been replaced. Whelen WPS 2810s and WPS 2806s were installed in their places. The 2810s are in place of the Model 120s and the 2806s are in place of the STL-10s. These new electronic sirens have battery backup, and are more efficient and less maintenance. After all the old sirens have been removed and replaced ,SONGS sold 23 of the STL-10s to Curry County Oregon to be used as tsunami sirens, and the Model 120s and remaining 5 STL-10s are believed to have been scrapped ,but its unknown if they were ,or went somewhere else but hasn't been discovered. The only Model 120 that is remaining is in the possession of Aaron Allevato (Duderocks5539) and Edaan Friedman and currently under restoration to be brought back into operating condition.
The '''Southern California Edison Model 120'''<ref>While Southern California Edison Model 120s are often referred to as "Toshiba" sirens by enthusiasts, these were not made by Toshiba. These were purely a custom-made design built in-house by Southern California Edison.</ref>, also known as the '''SoCal Edison Model 120''' or simply the '''Model 120''', is a 120 dB low tone supercharged electromechanical siren that was designed in-house by SONGS audio engineer John Glenn Powell specifically for use within the 10 Mile Emergency Planning Zone (EPZ) for the San Onofre Nuclear Generating Station (SONGS) during its operating life. It is one of a few examples of a siren that was purpose-built for a system.


== History ==


Siren patent: https://patents.google.com/patent/US4649853
[[File:Model 120 prototype being mounted to an existing STL-10 pole for range and output testing in 1982.jpeg|thumb|left|upright|Model 120 prototype being mounted to an existing [[Federal Signal STL-10|STL-10]] pole for range and output testing in Summer 1982.]]The Model 120 was created in 1982 as a custom-built siren for the SONGS plant, which had strict requirements for its siren system. SONGS had gone through two other systems before this point, with a system of 39 [[Sentry Siren|Sentry]] sirens originally being installed in August 1981 and tested in January 1982. The Sentry sirens were found to perform worse compared to what was advertised, leading to the sirens being removed. SONGS would then install a new system of 39 Federal Signal [[Federal Signal STL-10|STL-10s]], with those being installed by April of 1982 and tested in May of the same year. While the STL-10s performed significantly better than the Sentry sirens did, they still didn't meet the plant's needs, with insufficient coverage and a lack of corrosion resistance.


The only sirens on the market at the time with enough range that would meet the plant's needs at the time were rotational, but SONGS wanted to use exclusively omnidirectional sirens to reduce maintenance costs. Some of [[Alerting Communicators of America|ACA's]] omnidirectional sirens, such as the [[ACA Cyclone|Cyclone]], were likely considered but did not meet the requirements either.  With a lack of available options, SONGS opted to design and create their own siren to meet their requirements. The job of designing the siren was given to SONGS' audio engineer, John G. Powell, who created a compact, high-performance omnidirectional siren design using massive horns and a centrifugal blower. After being inspected by the plant, the siren was green-lit for production. Starting around June 1982, Model 120 prototypes started to be constructed and tested, with the final units being completed in March 1983.


Originally, the plan was after the first Model 120s were installed, a total of 52 additional Model 120s were going to replace the existing Federal STL-10s and make the system entirely Model 120s. This plan was dropped shortly afterward due to the increasing delays and costs caused to the plant by not having a ready siren system by 1981 which was the original year planned for the plant's 2 newly constructed reactors to begin operating. Units #2 and #3 were ready to begin operation, but because the siren system was inadequate, they couldn't begin operation until the Model 120s were installed. This caused a delay for over a year, as it also happened around the same time the NRC required nuclear plants to have siren systems. This also meant the plant's existing Unit #1 could not be restarted until the siren system was ready. There were 22 of these sirens produced, with one being never installed and put into storage as a spare.


[[File:3D5E51FE-62BF-4D63-B5E6-2733B5E18F00.jpeg|thumbnail|The Paxton centrifugal blower w/o motor (rear view showing the two belts and pulleys without the cover on.)]]
16 of these were installed in October 1982 to add into the system of STL-10s, 8 of which indirectly swapped out with Model 120s with another 8 being brand new installs. 5 additional sirens were installed in 1988, one of which replaced a Federal Signal [[Federal Signal Thunderbolt|Thunderbolt]] that was an existing Civil Defense siren. After the Model 120s went up, to end the delays of the siren system not being up to par, SONGS opted to keep the remaining STL-10s and add 21 Model 120s in areas that need coverage to get the EPZ up to code for the plant's reactors to start. After a successful system test in July 1983, the plant's new reactors began operation shortly afterwards with Unit #2 starting on August 8th, 1983, and Unit #3 on April 1st, 1984, as well as Unit #1 being restarted. These delays and the cost of the sirens themselves cost the plant over $1,000,000.


[[File:DD45D32B-46D1-48B1-A15C-ADA5FEC67066.jpeg|thumbnail|The blower w/o motor (rear view with the cover on.)]]
By June 2004, the plant began discussing a system replacement project due to the sirens suffering from advanced corrosion and degrading reliability due to the system's proximity to the ocean. A year later, beginning in November 2005 (a month after the annual siren test), the Model 120s and the STL-10s started to be gradually removed and replaced. By February 2006, all had been replaced by Whelen [[Whelen WPS-2800|WPS-2810]]<nowiki/>s and WPS-2806s that were installed in their places. The 2810s replaced the Model 120s and the 2806s replaced the STL-10s. These new electronic sirens had battery backup and voice capability (that was never used), were much lower maintenance due to their corrosion resistance, and had similar ranges to the sirens they replaced. These new sirens met the strict requirements of the plant without the need to specifically design a new siren. These would be later removed after SONGS was decommissioned. After all the old sirens had been replaced, SONGS sold 23 of the STL-10s to Curry County, Oregon, to be used as tsunami sirens, and the Model 120s and remaining 5 STL-10s were scrapped, save for a single Model 120 that was never installed, kept as a spare for parts and forgotten about. This last remaining unit is currently in private possession by Duderocks5539, undergoing restoration to eventually make it fully operational.


[[File:0EFDB333-123B-4FC0-AF14-868231AE3019.jpeg|thumbnail|The front of the blower showing the intake and motor mount. It can use a 5 or 10 Hp 1 phase motor.]]
== Design ==
The Model 120 is a unique mix of a supercharged and pneumatic electromechanical siren that lacks any vanes on the rotor, meaning it requires an external air source to produce any meaningful sound. The sound is created by a 4-port (later 5-port) single-tone rotor, which spins inside the stator and acts as a chamber to contain the air inside. The rotor is driven by a 2 hp TEFC AC motor that runs at 3450 rpm, driving the siren from above. The siren has an 8-port stator, and the sound is then projected by 8 large fiberglass horns attached to the stator. The siren makes use of a belt-driven Paxton centrifugal blower, that uses a 10 hp TEFC motor which sits below the siren's head to force pressurized air up into the rotor. This is a similar configuration to the Japanese [[Hankoku Electric Co., Ltd.|Hankoku]] siren, which also uses a centrifugal blower below the siren.


[[File:05DD7AB0-BB48-485E-BDD3-A023264A72B0.jpeg|thumbnail|Looking down the blower intake showing the impeller, which has a really tight tolerance and in conjunction with the rotors very high tolerance, they both work excellently, and eliminate the need for a large heavy roots blower. ]]
The 4-port units reached a frequency of 240 Hz (480 Hz without the blower due to the lack of air resistance making the rotor spin faster) and the 5-port units reached 300 Hz, or 600 Hz without the blower. The rotor and stator are both coated in Teflon, which helps seal the air in and prevent leaks, while also helping to protect them from corrosion from the salty air. The Model 120 is massive in size, requiring a significant framework to hold up the siren's massive fiberglass horns, as well as the blower and the rotor/stator itself. The siren was designed for being mounted on poles rather than rooftops, attached to the pole either through a custom mount, or reusing the mounts from the Sentry sirens they replaced.


[[File:0DDD1D27-DFDB-447F-A6B8-807F1C5A38D9.jpeg|thumbnail|A Model 120 (SONGS Siren location SC-13) In 2003, before being replaced by a Whelen WPS 2810 2 years later.]]
== Gallery ==


[[File:CA38B627-CA13-4A5D-8099-24B6CE254123.jpeg|thumbnail|Top of the head showing the top of the horns ,the rotor and stator ,and rotor motor.]]
<gallery mode="packed" heights="200px">
7 Model 120 heads and blowers.jpeg|7 Model 120 heads and blowers prior to being assembled.
Assembled unit without horns.jpeg|Assembled unit without horns.
Horns being attached and conduits ran to main junction box.jpeg|Horns being attached and conduits ran to main junction box.
5 out of the 8 horns attached with another unit being assembled off to the left.jpeg|5 out of the 8 horns attached with another unit being assembled off to the left.
Closer view of the head with the siren 95% assembled.jpeg|Closer view of the head with the siren 95% assembled.
Fully assembled Model 120.jpeg|Fully assembled Model 120.
Fully assembled Model 120 with the other 6 being assembled and crated up to be transported to San Onofre Nuclear Generating Station for installation in the 10 mile EPZ around May-June 1983.jpeg|Fully assembled Model 120 with the other 6 being assembled and crated up to be transported to San Onofre Nuclear Generating Station for installation in the 10 mile EPZ in October 1982. These were the first 7 to be installed which replaced 7 STL-10B's.
IMG 7890.jpeg|Siren Location SC-13 illuminated by a spot light at night in 2003. The siren was 21 years old at the time.
99F6BBFC-E550-4A8C-8538-82E2356B663A.jpeg|Head of the privately owned unit with a salvaged motor attached.
</gallery>


[[File:99F6BBFC-E550-4A8C-8538-82E2356B663A.jpeg|thumbnail|rotor and stator of the privately owned unit ,with a motor attached.]]
== See Also ==


[[File:Installed unit on wood pole overlooking trees.jpeg|thumbnail|Just installed unit on wood pole overlooking trees. This is without the horns.]]
* Siren patent: https://patents.google.com/patent/US4649853
 
* Model 120 head run up: https://www.youtube.com/watch?v=mf7YC0Vc_ZI
[[File:Another unit on wood pole over looking trees.jpeg|thumbnail|Another just installed unit on wood pole over looking trees.]]
* Model 120 head dissembled: https://www.youtube.com/watch?v=yOcVk3SrqtY
 
[[Category:Sirens]]
[[File:Unit on a steel pole looking upward from ground view.jpeg|thumbnail|Just installed unit on a steel pole looking upward from ground view.]]
[[Category:Omnidirectional Sirens]]
 
[[Category:Electromechanical Sirens]]
[[File:Timer.jpeg|thumbnail|Timer.]]
[[Category:Supercharged Sirens]][[Category:Single Toned Sirens]][[Category:SoCal Edison]]
 
[[Category:Pneumatic Sirens]]
[[File:Radio-decoder.jpeg|thumbnail|Radio/decoder.]]
__INDEX__
 
[[File:Service-manaul power switches.jpeg|thumbnail|Breaker panel switches.]]
 
[[File:Model 120 installation blue print.jpeg|thumbnail|Installtion blueprint.]]  
 
 
 
 
[[Category:SoCal Edison]][[Category:Omnidirectional Sirens]][[Category:Pnuematic Sirens]][[Category:Single Toned Sirens]][[Category:Sirens]]

Revision as of 20:49, 19 August 2024

Southern California Edison Model 120

A Model 120 unit on a Sentry mount.

Company Southern California Edison
Produced 1982-1988
Type Supercharged Electromechanical Omnidirectional Pneumatic
Sound output 120 dB @ 100 ft
Horsepower 2 hp (chopper)

10 hp (blower)

The Southern California Edison Model 120[1], also known as the SoCal Edison Model 120 or simply the Model 120, is a 120 dB low tone supercharged electromechanical siren that was designed in-house by SONGS audio engineer John Glenn Powell specifically for use within the 10 Mile Emergency Planning Zone (EPZ) for the San Onofre Nuclear Generating Station (SONGS) during its operating life. It is one of a few examples of a siren that was purpose-built for a system.

History

Model 120 prototype being mounted to an existing STL-10 pole for range and output testing in Summer 1982.

The Model 120 was created in 1982 as a custom-built siren for the SONGS plant, which had strict requirements for its siren system. SONGS had gone through two other systems before this point, with a system of 39 Sentry sirens originally being installed in August 1981 and tested in January 1982. The Sentry sirens were found to perform worse compared to what was advertised, leading to the sirens being removed. SONGS would then install a new system of 39 Federal Signal STL-10s, with those being installed by April of 1982 and tested in May of the same year. While the STL-10s performed significantly better than the Sentry sirens did, they still didn't meet the plant's needs, with insufficient coverage and a lack of corrosion resistance.

The only sirens on the market at the time with enough range that would meet the plant's needs at the time were rotational, but SONGS wanted to use exclusively omnidirectional sirens to reduce maintenance costs. Some of ACA's omnidirectional sirens, such as the Cyclone, were likely considered but did not meet the requirements either. With a lack of available options, SONGS opted to design and create their own siren to meet their requirements. The job of designing the siren was given to SONGS' audio engineer, John G. Powell, who created a compact, high-performance omnidirectional siren design using massive horns and a centrifugal blower. After being inspected by the plant, the siren was green-lit for production. Starting around June 1982, Model 120 prototypes started to be constructed and tested, with the final units being completed in March 1983.

Originally, the plan was after the first Model 120s were installed, a total of 52 additional Model 120s were going to replace the existing Federal STL-10s and make the system entirely Model 120s. This plan was dropped shortly afterward due to the increasing delays and costs caused to the plant by not having a ready siren system by 1981 which was the original year planned for the plant's 2 newly constructed reactors to begin operating. Units #2 and #3 were ready to begin operation, but because the siren system was inadequate, they couldn't begin operation until the Model 120s were installed. This caused a delay for over a year, as it also happened around the same time the NRC required nuclear plants to have siren systems. This also meant the plant's existing Unit #1 could not be restarted until the siren system was ready. There were 22 of these sirens produced, with one being never installed and put into storage as a spare.

16 of these were installed in October 1982 to add into the system of STL-10s, 8 of which indirectly swapped out with Model 120s with another 8 being brand new installs. 5 additional sirens were installed in 1988, one of which replaced a Federal Signal Thunderbolt that was an existing Civil Defense siren. After the Model 120s went up, to end the delays of the siren system not being up to par, SONGS opted to keep the remaining STL-10s and add 21 Model 120s in areas that need coverage to get the EPZ up to code for the plant's reactors to start. After a successful system test in July 1983, the plant's new reactors began operation shortly afterwards with Unit #2 starting on August 8th, 1983, and Unit #3 on April 1st, 1984, as well as Unit #1 being restarted. These delays and the cost of the sirens themselves cost the plant over $1,000,000.

By June 2004, the plant began discussing a system replacement project due to the sirens suffering from advanced corrosion and degrading reliability due to the system's proximity to the ocean. A year later, beginning in November 2005 (a month after the annual siren test), the Model 120s and the STL-10s started to be gradually removed and replaced. By February 2006, all had been replaced by Whelen WPS-2810s and WPS-2806s that were installed in their places. The 2810s replaced the Model 120s and the 2806s replaced the STL-10s. These new electronic sirens had battery backup and voice capability (that was never used), were much lower maintenance due to their corrosion resistance, and had similar ranges to the sirens they replaced. These new sirens met the strict requirements of the plant without the need to specifically design a new siren. These would be later removed after SONGS was decommissioned. After all the old sirens had been replaced, SONGS sold 23 of the STL-10s to Curry County, Oregon, to be used as tsunami sirens, and the Model 120s and remaining 5 STL-10s were scrapped, save for a single Model 120 that was never installed, kept as a spare for parts and forgotten about. This last remaining unit is currently in private possession by Duderocks5539, undergoing restoration to eventually make it fully operational.

Design

The Model 120 is a unique mix of a supercharged and pneumatic electromechanical siren that lacks any vanes on the rotor, meaning it requires an external air source to produce any meaningful sound. The sound is created by a 4-port (later 5-port) single-tone rotor, which spins inside the stator and acts as a chamber to contain the air inside. The rotor is driven by a 2 hp TEFC AC motor that runs at 3450 rpm, driving the siren from above. The siren has an 8-port stator, and the sound is then projected by 8 large fiberglass horns attached to the stator. The siren makes use of a belt-driven Paxton centrifugal blower, that uses a 10 hp TEFC motor which sits below the siren's head to force pressurized air up into the rotor. This is a similar configuration to the Japanese Hankoku siren, which also uses a centrifugal blower below the siren.

The 4-port units reached a frequency of 240 Hz (480 Hz without the blower due to the lack of air resistance making the rotor spin faster) and the 5-port units reached 300 Hz, or 600 Hz without the blower. The rotor and stator are both coated in Teflon, which helps seal the air in and prevent leaks, while also helping to protect them from corrosion from the salty air. The Model 120 is massive in size, requiring a significant framework to hold up the siren's massive fiberglass horns, as well as the blower and the rotor/stator itself. The siren was designed for being mounted on poles rather than rooftops, attached to the pole either through a custom mount, or reusing the mounts from the Sentry sirens they replaced.

Gallery

See Also

  1. While Southern California Edison Model 120s are often referred to as "Toshiba" sirens by enthusiasts, these were not made by Toshiba. These were purely a custom-made design built in-house by Southern California Edison.