Southern California Edison Model 120: Difference between revisions

From airraidsirens.net, the Internet's premiere site for siren information and discussion
Jump to navigation Jump to search
m (ArxCyberwolf moved page Model 120 to Southern California Edison Model 120)
(Moved page over from the CDS Wiki.)
Line 1: Line 1:
{{Infobox siren
{{Infobox siren
|image =[[File:Model 120.jpg|Unit installed on a wood pole]]
|image =Model 120.jpg  
|company= Southern California Edison
|company= Southern California Edison
|produced= 1982-1988
|produced= 1982-1988
|type=[[Electromechanical]]  
|type=[[Supercharged]] [[Electromechanical]] [[Omnidirectional]] [[Pneumatic]]  
|output=120
|output=120 dB @ 100 ft
|hertz = 240 or 300  
|hertz = 240 or 300  
|neigh = 2 (Rotor) 10 (Blower)
|caption=A Model 120 unit on a Sentry mount.|hp=2 hp (chopper)
}}
10 hp (blower)}}
The ''' SoCal Edison (SCE) 120 ''' or ''' Model 120 ''' was a 120 dB low tone supercharged electromechanical siren designed in house by Southern California Edison for use within the 10 Mile Emergency Planning Zone (EPZ) for the ''' [[San Onofre Nuclear Generating station]] '''.
The '''Southern California Edison Model 120'''<ref>While Southern California Edison Model 120s are often referred to as "Toshiba" sirens by enthusiasts, these were not made by Toshiba. These were purely a custom-made design built in-house by Southern California Edison.</ref>, also known as the '''SoCal Edison Model 120''' or simply the '''Model 120''', is a 120 dB low tone supercharged electromechanical siren that was designed in-house by SONGS audio engineer John Glenn Powell specifically for use within the 10 Mile Emergency Planning Zone (EPZ) for the San Onofre Nuclear Generating Station (SONGS) during its operating life. It is one of a few examples of a siren that was purpose-built for a system.


== History ==
== History ==


The Model 120 was originally created in 1982 as a custom built siren for the SONGS plant, which had strict requirements for its siren system. SONGS had gone through two other systems before this point, with a system of 39 [[Sentry Siren Incorporated]] [[10V]]'s, [[5V]]'s, and [[3V8]]'s installed in August 1981 and tested January 25th thru 27th, 1982. The Sentry sirens were found to perform terribly compared to what was advertised, leading to the sirens being removed an replaced. SONGS would then install a new system of 39 [[Federal Signal]] [[STL-10]]'s with those being installed by April of 1982 and tested in May of the same year. While the STL-10's performed significantly better than the Sentry sirens did, they still didn't meet the plant's needs. The only sirens on the market with enough range that would meet the plant's needs at the time were rotational sirens, but SONGS wanted to use exclusively omnidirectional sirens. So, they decided to design and create their own siren to meet their requirements.
[[File:Model 120 prototype being mounted to an existing STL-10 pole for range and output testing in 1982.jpeg|thumb|left|upright|Model 120 prototype being mounted to an existing [[Federal Signal STL-10|STL-10]] pole for range and output testing in Summer 1982.]]The Model 120 was created in 1982 as a custom-built siren for the SONGS plant, which had strict requirements for its siren system. SONGS had gone through two other systems before this point, with a system of 39 [[Sentry Siren|Sentry]] sirens originally being installed in August 1981 and tested in January 1982. The Sentry sirens were found to perform worse compared to what was advertised, leading to the sirens being removed. SONGS would then install a new system of 39 Federal Signal [[Federal Signal STL-10|STL-10s]], with those being installed by April of 1982 and tested in May of the same year. While the STL-10s performed significantly better than the Sentry sirens did, they still didn't meet the plant's needs, with insufficient coverage and a lack of corrosion resistance.


[[File:Model 120 prototype being mounted to an existing STL-10 pole for range and output testing in 1982.jpeg|thumb|left|upright|Model 120 prototype being mounted to an existing STL-10 pole for range and output testing in Summer 1982.]]
The only sirens on the market at the time with enough range that would meet the plant's needs at the time were rotational, but SONGS wanted to use exclusively omnidirectional sirens to reduce maintenance costs. Some of [[Alerting Communicators of America|ACA's]] omnidirectional sirens, such as the [[ACA Cyclone|Cyclone]], were likely considered but did not meet the requirements either.  With a lack of available options, SONGS opted to design and create their own siren to meet their requirements. The job of designing the siren was given to SONGS' audio engineer, John G. Powell, who created a compact, high-performance omnidirectional siren design using massive horns and a centrifugal blower. After being inspected by the plant, the siren was green-lit for production. Starting around June 1982, Model 120 prototypes started to be constructed and tested, with the final units being completed in March 1983.


Starting in around June 1982, Model 120 prototypes started to be constructed and tested, with the final designed units being completed in October 1982. Originally, the plan was after the first Model 120's were installed, a total of 52 additional Model 120's were going to replace the existing [[Federal Signal]] [[STL-10]]'s and making the system entirely Model 120's. This plan was dropped shortly afterwards due to the increasing delays and costs caused to the plant by not having a ready siren system by 1981 which was the original year planned for the plant's 2 newly constructed reactors to begin operating. Units #2 and #3 were ready to begin operation, but because the siren system was inadequate they couldn't begin operation until the Model 120's were installed. This caused a delay for over a year, as it also happened around the same time the NRC required nuclear plants to have siren systems. This also meant the plant's existing Unit #1 could not be restarted until the siren system was ready.
Originally, the plan was after the first Model 120s were installed, a total of 52 additional Model 120s were going to replace the existing Federal STL-10s and make the system entirely Model 120s. This plan was dropped shortly afterward due to the increasing delays and costs caused to the plant by not having a ready siren system by 1981 which was the original year planned for the plant's 2 newly constructed reactors to begin operating. Units #2 and #3 were ready to begin operation, but because the siren system was inadequate, they couldn't begin operation until the Model 120s were installed. This caused a delay for over a year, as it also happened around the same time the NRC required nuclear plants to have siren systems. This also meant the plant's existing Unit #1 could not be restarted until the siren system was ready. There were 22 of these sirens produced, with one being never installed and put into storage as a spare.


There were 22 of these sirens produced, with one being never installed and put into storage as a spare. 16 of these were installed in October 1982 to add into the system of STL-10's, 8 of which indirectly swapped out with Model 120's with another 8 being brand new installs. 5 additional sirens were installed in 1988, one of which replaced a [[Federal Signal]] [[Thunderbolt]] that was an existing Civil Defense siren.
16 of these were installed in October 1982 to add into the system of STL-10s, 8 of which indirectly swapped out with Model 120s with another 8 being brand new installs. 5 additional sirens were installed in 1988, one of which replaced a Federal Signal [[Federal Signal Thunderbolt|Thunderbolt]] that was an existing Civil Defense siren. After the Model 120s went up, to end the delays of the siren system not being up to par, SONGS opted to keep the remaining STL-10s and add 21 Model 120s in areas that need coverage to get the EPZ up to code for the plant's reactors to start. After a successful system test in July 1983, the plant's new reactors began operation shortly afterwards with Unit #2 starting on August 8th, 1983, and Unit #3 on April 1st, 1984, as well as Unit #1 being restarted. These delays and the cost of the sirens themselves cost the plant over $1,000,000.


After the Model 120's went up, in order to end the delays of the siren system not being up to par, SONGS opted to just keep the remaining [[Federal Signal]] [[STL-10]]'s and add 21 Model 120's in areas that need coverage and to swap out specific STL-10 sites that had the worst range compared to the others, (First 8 sites), to get the EPZ up to code for the plant's reactors to start. After a successful system test on May 4th, 1983, the plant's new reactors began operation shortly afterwards with Unit #2 starting on August 8th, 1983, and Unit #3 on April 1st, 1984, as well as Unit #1 being restarted. These delays, and the cost of the sirens themselves cost the plant over $1 million dollars.
By June 2004, the plant began discussing a system replacement project due to the sirens suffering from advanced corrosion and degrading reliability due to the system's proximity to the ocean. A year later, beginning in November 2005 (a month after the annual siren test), the Model 120s and the STL-10s started to be gradually removed and replaced. By February 2006, all had been replaced by Whelen [[Whelen WPS-2800|WPS-2810]]<nowiki/>s and WPS-2806s that were installed in their places. The 2810s replaced the Model 120s and the 2806s replaced the STL-10s. These new electronic sirens had battery backup and voice capability (that was never used), were much lower maintenance due to their corrosion resistance, and had similar ranges to the sirens they replaced. These new sirens met the strict requirements of the plant without the need to specifically design a new siren. These would be later removed after SONGS was decommissioned. After all the old sirens had been replaced, SONGS sold 23 of the STL-10s to Curry County, Oregon, to be used as tsunami sirens, and the Model 120s and remaining 5 STL-10s were scrapped, save for a single Model 120 that was never installed, kept as a spare for parts and forgotten about. This last remaining unit is currently in private possession by Duderocks5539, undergoing restoration to eventually make it fully operational.


== Design ==
The Model 120 is a unique mix of a supercharged and pneumatic electromechanical siren that lacks any vanes on the rotor, meaning it requires an external air source to produce any meaningful sound. The sound is created by a 4-port (later 5-port) single-tone rotor, which spins inside the stator and acts as a chamber to contain the air inside. The rotor is driven by a 2 hp TEFC AC motor that runs at 3450 rpm, driving the siren from above. The siren has an 8-port stator, and the sound is then projected by 8 large fiberglass horns attached to the stator. The siren makes use of a belt-driven Paxton centrifugal blower, that uses a 10 hp TEFC motor which sits below the siren's head to force pressurized air up into the rotor. This is a similar configuration to the Japanese [[Hankoku Electric Co., Ltd.|Hankoku]] siren, which also uses a centrifugal blower below the siren.


== Other Information ==
The 4-port units reached a frequency of 240 Hz (480 Hz without the blower due to the lack of air resistance making the rotor spin faster) and the 5-port units reached 300 Hz, or 600 Hz without the blower. The rotor and stator are both coated in Teflon, which helps seal the air in and prevent leaks, while also helping to protect them from corrosion from the salty air. The Model 120 is massive in size, requiring a significant framework to hold up the siren's massive fiberglass horns, as well as the blower and the rotor/stator itself. The siren was designed for being mounted on poles rather than rooftops, attached to the pole either through a custom mount, or reusing the mounts from the Sentry sirens they replaced.
 
For around a decade, they were thought to be "Toshiba" sirens, because they were pneumatic and people just assumed they were made by Toshiba which made pneumatic sirens. The Model 120 is a Supercharged Electromechanical siren, but also more or less acts like a pneumatic siren due to the rotor lacking any vanes, meaning it requires an external air source to produce any meaningful sound, such as the [[Thunderbolt]] and [[Hurricane]]. The sound is created by a 4-port (later 5-port) single tone rotor, which spins inside the stator, which acts as a chamber to contain the air inside. The rotor is driven by a 2 Hp TEFC motor that runs at 3450 RPM. The siren has an 8-port stator with narrow ports, and the sound is then projected by 8 large fiberglass horns attached to the stator. The siren makes use of a belt driven Paxton centrifugal blower, that uses a 10 Hp TEFC motor which sits below the siren's head to force pressurized air up into the rotor. The 4-port units reached a frequency of 240 Hz (480 Hz without the blower) and the 5-port units reached 300 Hz. The rotor and stator are both coated in Teflon, which helps seal the air in and prevent leaks, while also helping to protect them from corrosion from the salty air. The rotor is 9.75 inches in diameter and including the stator, which it alone is over 2 inches in diameter, is in total 11.75 inches in diameter.
 
 
 
By June of 2004, the plant began discussing a system replacement project due to the sirens suffering from advanced corrosion and degrading reliability due to the system's proximity to the ocean, along with the system "aging", and a year later starting In November 2005, (a month after the annual siren test), the Model 120's and the STL-10's started to be gradually removed and replaced, and by February 2006 all have been replaced marking October 26th, 2005 as the final test of the original system, as well as the end of the one of a kind original system that stood out from all other Nuclear plant systems. [[Whelen Engineering]] [[WPS-2800 series|WPS-2810]]'s and [[WPS-2800 series|WPS-2806]]'s were installed in their places. The 2810's went in place of the Model 120's and the 2806's went in place of the STL-10's.
 
These new electronic sirens have battery backup, are less maintenance due to their resistance to corrosion and no moving parts, and have similar ranges to the original system such as the 2806's having better range compared to the STL-10's, and the 2810's having close to the same range but about 2,000 feet less range compared to the the Model 120, but still enough range to cover the EPZ. These new sirens met the strict requirements of the plant without the need to specifically design a new siren as by the 2000's, there was commercially produced omnidirectional sirens that have close to the same range as the Model 120 and as well have better range then the STL-10's.
 
After all the old sirens have been removed and replaced, SONGS sold 23 of the STL-10's to Curry County, Oregon to be used as tsunami sirens, 8 of which were installed, and the Model 120's and remaining 5 STL-10's are believed to have been scrapped, but its unknown if they were, or went somewhere else but hasn't been discovered. The only Model 120 that is known and remaining is in private possession currently under restoration to be brought back into operating condition.


== Gallery ==
== Gallery ==


<gallery mode=packed heights=200px>
<gallery mode="packed" heights="200px">
7 Model 120 heads and blowers.jpeg|7 Model 120 heads and blowers prior to being assembled.
7 Model 120 heads and blowers.jpeg|7 Model 120 heads and blowers prior to being assembled.
Assembled unit without horns.jpeg|Assembled unit without horns.
Assembled unit without horns.jpeg|Assembled unit without horns.
Line 54: Line 46:
* Model 120 head run up: https://www.youtube.com/watch?v=mf7YC0Vc_ZI
* Model 120 head run up: https://www.youtube.com/watch?v=mf7YC0Vc_ZI
* Model 120 head dissembled: https://www.youtube.com/watch?v=yOcVk3SrqtY
* Model 120 head dissembled: https://www.youtube.com/watch?v=yOcVk3SrqtY
 
[[Category:Sirens]]
[[Category:Omnidirectional Sirens]][[Category:Electromechanical Sirens]][[Category:Supercharged Sirens]][[Category:Single Toned Sirens]][[Category:SoCal Edison]][[Category:Sirens]]
[[Category:Omnidirectional Sirens]]
[[Category:Electromechanical Sirens]]
[[Category:Supercharged Sirens]][[Category:Single Toned Sirens]][[Category:SoCal Edison]]
[[Category:Pneumatic Sirens]]
__INDEX__

Revision as of 20:49, 19 August 2024

Southern California Edison Model 120

A Model 120 unit on a Sentry mount.

Company Southern California Edison
Produced 1982-1988
Type Supercharged Electromechanical Omnidirectional Pneumatic
Sound output 120 dB @ 100 ft
Horsepower 2 hp (chopper)

10 hp (blower)

The Southern California Edison Model 120[1], also known as the SoCal Edison Model 120 or simply the Model 120, is a 120 dB low tone supercharged electromechanical siren that was designed in-house by SONGS audio engineer John Glenn Powell specifically for use within the 10 Mile Emergency Planning Zone (EPZ) for the San Onofre Nuclear Generating Station (SONGS) during its operating life. It is one of a few examples of a siren that was purpose-built for a system.

History

Model 120 prototype being mounted to an existing STL-10 pole for range and output testing in Summer 1982.

The Model 120 was created in 1982 as a custom-built siren for the SONGS plant, which had strict requirements for its siren system. SONGS had gone through two other systems before this point, with a system of 39 Sentry sirens originally being installed in August 1981 and tested in January 1982. The Sentry sirens were found to perform worse compared to what was advertised, leading to the sirens being removed. SONGS would then install a new system of 39 Federal Signal STL-10s, with those being installed by April of 1982 and tested in May of the same year. While the STL-10s performed significantly better than the Sentry sirens did, they still didn't meet the plant's needs, with insufficient coverage and a lack of corrosion resistance.

The only sirens on the market at the time with enough range that would meet the plant's needs at the time were rotational, but SONGS wanted to use exclusively omnidirectional sirens to reduce maintenance costs. Some of ACA's omnidirectional sirens, such as the Cyclone, were likely considered but did not meet the requirements either. With a lack of available options, SONGS opted to design and create their own siren to meet their requirements. The job of designing the siren was given to SONGS' audio engineer, John G. Powell, who created a compact, high-performance omnidirectional siren design using massive horns and a centrifugal blower. After being inspected by the plant, the siren was green-lit for production. Starting around June 1982, Model 120 prototypes started to be constructed and tested, with the final units being completed in March 1983.

Originally, the plan was after the first Model 120s were installed, a total of 52 additional Model 120s were going to replace the existing Federal STL-10s and make the system entirely Model 120s. This plan was dropped shortly afterward due to the increasing delays and costs caused to the plant by not having a ready siren system by 1981 which was the original year planned for the plant's 2 newly constructed reactors to begin operating. Units #2 and #3 were ready to begin operation, but because the siren system was inadequate, they couldn't begin operation until the Model 120s were installed. This caused a delay for over a year, as it also happened around the same time the NRC required nuclear plants to have siren systems. This also meant the plant's existing Unit #1 could not be restarted until the siren system was ready. There were 22 of these sirens produced, with one being never installed and put into storage as a spare.

16 of these were installed in October 1982 to add into the system of STL-10s, 8 of which indirectly swapped out with Model 120s with another 8 being brand new installs. 5 additional sirens were installed in 1988, one of which replaced a Federal Signal Thunderbolt that was an existing Civil Defense siren. After the Model 120s went up, to end the delays of the siren system not being up to par, SONGS opted to keep the remaining STL-10s and add 21 Model 120s in areas that need coverage to get the EPZ up to code for the plant's reactors to start. After a successful system test in July 1983, the plant's new reactors began operation shortly afterwards with Unit #2 starting on August 8th, 1983, and Unit #3 on April 1st, 1984, as well as Unit #1 being restarted. These delays and the cost of the sirens themselves cost the plant over $1,000,000.

By June 2004, the plant began discussing a system replacement project due to the sirens suffering from advanced corrosion and degrading reliability due to the system's proximity to the ocean. A year later, beginning in November 2005 (a month after the annual siren test), the Model 120s and the STL-10s started to be gradually removed and replaced. By February 2006, all had been replaced by Whelen WPS-2810s and WPS-2806s that were installed in their places. The 2810s replaced the Model 120s and the 2806s replaced the STL-10s. These new electronic sirens had battery backup and voice capability (that was never used), were much lower maintenance due to their corrosion resistance, and had similar ranges to the sirens they replaced. These new sirens met the strict requirements of the plant without the need to specifically design a new siren. These would be later removed after SONGS was decommissioned. After all the old sirens had been replaced, SONGS sold 23 of the STL-10s to Curry County, Oregon, to be used as tsunami sirens, and the Model 120s and remaining 5 STL-10s were scrapped, save for a single Model 120 that was never installed, kept as a spare for parts and forgotten about. This last remaining unit is currently in private possession by Duderocks5539, undergoing restoration to eventually make it fully operational.

Design

The Model 120 is a unique mix of a supercharged and pneumatic electromechanical siren that lacks any vanes on the rotor, meaning it requires an external air source to produce any meaningful sound. The sound is created by a 4-port (later 5-port) single-tone rotor, which spins inside the stator and acts as a chamber to contain the air inside. The rotor is driven by a 2 hp TEFC AC motor that runs at 3450 rpm, driving the siren from above. The siren has an 8-port stator, and the sound is then projected by 8 large fiberglass horns attached to the stator. The siren makes use of a belt-driven Paxton centrifugal blower, that uses a 10 hp TEFC motor which sits below the siren's head to force pressurized air up into the rotor. This is a similar configuration to the Japanese Hankoku siren, which also uses a centrifugal blower below the siren.

The 4-port units reached a frequency of 240 Hz (480 Hz without the blower due to the lack of air resistance making the rotor spin faster) and the 5-port units reached 300 Hz, or 600 Hz without the blower. The rotor and stator are both coated in Teflon, which helps seal the air in and prevent leaks, while also helping to protect them from corrosion from the salty air. The Model 120 is massive in size, requiring a significant framework to hold up the siren's massive fiberglass horns, as well as the blower and the rotor/stator itself. The siren was designed for being mounted on poles rather than rooftops, attached to the pole either through a custom mount, or reusing the mounts from the Sentry sirens they replaced.

Gallery

See Also

  1. While Southern California Edison Model 120s are often referred to as "Toshiba" sirens by enthusiasts, these were not made by Toshiba. These were purely a custom-made design built in-house by Southern California Edison.