MC

From airraidsirens.net, the Internet's premiere site for siren information and discussion
Revision as of 00:52, 27 August 2024 by ArxCyberwolf (talk | contribs)
Jump to navigation Jump to search
MC

An MC6024 controller in Hawaii.

Company Federal Signal Corporation
Produced 1991?-1996
Type Electronic Siren Controller
Preceded by SiraTone
Succeeded by MCP

The MC, or Modulator Controller, was an electronic siren controller produced by Federal Signal Corporation for the Modulator, DSA, and EOWS Series of sirens.

Operation

The MC was a new design of controller by Federal Signal, with the only similarities between it and its predecessor, the SiraTone, being the amplifiers used and the capability to run the EOWS*612 rotating speaker array. The controller was a microprocessor operated platform which used digital, solid state systems to produce the 7 signals provided by Federal Signal. Unlike the SiraTone, the MC had tones pre-loaded onto an audio ROM chip so there was no need for an analogue tone generator and timer circuit. Audio from the ROM chip was programmed by Federal Signal, with the auxiliary tone being Westminster Chimes by default unless a different tone was requested for by the customer. This could be overwritten by an engineer using software on site should signalling needs change. The MC also came with digital voice messages, zones for the EOWS*612 (MC3012 only), had a status report function, a stereo PA function on the controller and were able to have a remote PA function as well.

A Modulator 3012 driven by a stainless steel MC3012 controller in Hawaii

The system was activated by two-tone or by DTMF by the controller's internal radio, locally by keying in a two digit code on the controller's keypad, or by operating the controller via landline. When using two-tone or DTMF, the siren has to be "armed" in order to operate (unless programmed not to). To do this a DTMF arm string would first be broadcast to the controller, then a signal DTMF string would be broadcast. Arm period would last for 5 minutes until automatic disarm, unless a "disarm" DTMF string was broadcast before the time expired. This is different, and more secure, to the SiraTone which required a jumper to be added in order to permanently arm the controller. After a signal was activated the digital audio was sent through a digital/analogue converter to each amplifier and onto the speaker array in the form of a square wave.

Diagram of MC3012 controller. Note the size difference

Construction

The MC was constructed inside a NEMA 4 enclosure with the batteries inside a vented NEMA 4 enclosure. These new enclosures had built in locks and clamps which increased security. A typical fully constructed MC3012 controller would weigh 190 pounds (86 kilograms). The controller came in two sizes. There is a small, MCP style enclosure for the MC1004 and 2008 and there is the larger and more common controller size for the MC3012-MC6024. The MC1004, 2008, 3012 and 4016 run off two batteries whereas the MC5020 and 6024 run off 4 batteries to allow for larger current draw. The controller came in 3 different metal grades: stainless steel, aluminium and painted steel.

Diagram of MC1004 controller.

The internals of the controller are rack mounted with four or two screws at opposite ends, much like how network gear is mounted to a network rack. This rack mounting assembly hinges out so the engineer can easily access the DIN rails behind and make all the necessary connections such as wiring up the service power to the charger etc. This is a difference to the SiraTone which has the separate modules slide out on rails and is also a design improvement as it makes the controller more modular. For example, the MC6024 controller shown at the top of the page has the control interface mounted at the bottom rather than the top of the panel, making it easier for servicing. Once power is applied by the batteries the controller's internal clock starts running and programming can commence.

The MC uses the same amplifiers to the SiraTone which allows backwards compatibility between the two controllers. Each amplifier is connected to a module backplane. Each module consists of two amplifiers. On each module backplane there is a jumper which sets the tone the module will play: high or low, which corresponds to signal A or signal B. Rotation circuitry is also provided for in the MC3012 only to support using the EOWS*612, which was being manufactured along with the Modulator and DSA. The controller is operated by a 24 character keypad and display.

Key Improvements on Design

The MC controller was Federal Signal's first digital electronic siren controller. Going digital meant there was less to go wrong as more could be put into microchips and be software controlled.

It had more features and was more flexible thanks to it being CPU operated, making it technologically superior to controllers before it.

Construction was modular, allowing internals to be organised to end user's standards.

Activation methods had more features added in. For example a radio of owner's choice could be easily added in as the wiring methods for the MC controller were universal.

Controller could give regular reports pertaining to its health, and would alert the system controller to any faults found.

The MC was a complete new design from Federal Signal with only the amplifiers being a piece of legacy hardware from the SiraTone. This also allowed Federal to stretch their legs and make the controller more stable and reliable while in use.

Discontinuation and Modern Use

The MC controller was replaced towards the end of 1996 by the more compact and more advanced MCP which introduced easy software programming, larger wattage amplifiers, as well as full tone customization, among other functions and features.

MC controlled sirens are still very much in existence and are used to this day, however they are slowly being replaced in favor of more up to date systems, as well as being replaced with different sirens. This makes the controller more hard to come by. There still are some MC siren systems in use, such as Hawaii, however, units are being replaced and scrapped as part of a federal government upgrade scheme.