Model 120: Difference between revisions

From airraidsirens.net, the Internet's premiere site for siren information and discussion
Jump to navigation Jump to search
No edit summary
mNo edit summary
 
(10 intermediate revisions by one other user not shown)
Line 1: Line 1:
{{Infobox siren
{{Infobox siren
|image =[[File:Model 120.jpg|Unit installed on a wood pole]]
|image =[[File:Model 120.jpg|Unit installed on a wood pole]]  
|company= Southern California Edison
|company= Southern California Edison
|produced= 1983 and 1988
|produced= 1982-1988
|type=[[Pneumatic]]  
|type=[[Electromechanical]]  
|output=120
|output=120
|hertz = 300  
|hertz = 240 or 300  
|neigh = 2 (Rotor) 10 (Blower)
|neigh = 2 (Rotor) 10 (Blower)
}}
}}
The SoCal Edison (SCE) 120 or Model 120 was a 120 dB low tone pneumatic siren designed in house by Southern California Edison for use within the 10 Mile Emergency Planning Zone (EPZ) for the San Onofre Nuclear Generating Station (SONGS).
The ''' SoCal Edison (SCE) 120 ''' or ''' Model 120 ''' was a 120 dB low tone supercharged electromechanical siren designed in house by Southern California Edison for use within the 10 Mile Emergency Planning Zone (EPZ) for the ''' [[San Onofre Nuclear Generating station]] '''.


== Origins ==
== History ==


There were 22 of these sirens produced with one being never installed which is now privately owned. 16 were installed in July 1983 to add into a system of 32 Federal Signal STL-10s that were installed in April 1982 with 2 of the STL-10s being swapped out for Model 120s, and later in 1988 5 additional locations were installed one of which replacing a Thunderbolt that was actually a CD siren used by one of the cities before SONGS took over it for use in their siren system. The reason these sirens were made is because there was no other siren available that would meet the plants needs. The only sirens that were available on the market that have the range the plant was looking for were rotating directional sirens only, of which the plant wanted Omnidirectional only sirens. They did look into ACA Cyclones which was the most powerful omnidirectional siren available, but they realized it didn't have the coverage the plant wanted being about 3,000 or so feet less then the plants range requirement, and the fact that they have massive 50 Hp motors which was overkill for a siren with such a range of only about 4,000ish feet. The other reason is because the STL-10s underperformed in all areas they were placed in, as well as federal lying to SoCal Edison about the STL-10 being 120 decibels and having the specific effective range that the plant required (which was about 6,000 or more feet effective range) to cover the EPZ due to the hilly terrain of the jurisdictions in the EPZ.  
The Model 120 was originally created in 1982 as a custom built siren for the SONGS plant, which had strict requirements for its siren system. SONGS had gone through two other systems before this point, with a system of 39 [[Sentry Siren Incorporated]] [[10V]]'s, [[5V]]'s, and [[3V8]]'s installed in August 1981 and tested January 25th thru 27th, 1982. The Sentry sirens were found to perform terribly compared to what was advertised, leading to the sirens being removed an replaced. SONGS would then install a new system of 39 [[Federal Signal]] [[STL-10]]'s with those being installed by April of 1982 and tested in May of the same year. While the STL-10's performed significantly better than the Sentry sirens did, they still didn't meet the plant's needs. The only sirens on the market with enough range that would meet the plant's needs at the time were rotational sirens, but SONGS wanted to use exclusively omnidirectional sirens. So, they decided to design and create their own siren to meet their requirements.


[[File:Model 120 prototype being mounted to an existing STL-10 pole for range and output testing in 1982.jpeg|thumb|left|upright|Model 120 prototype being mounted to an existing STL-10 pole for range and output testing in Summer 1982.]]


So starting in around June 1982, Model 120 prototypes started to be constructed and tested, with the final designed units being completed in March 1983, and the first 16 installed in July 1983, and later on 5 more in 1988 to cover new housing and business development in a part of the city of San Clemente that was being constructed around 1987 bringing the total to 21 Model 120s and a total number of 52 sirens with the already existing 32 STL-10s.  
Starting in around June 1982, Model 120 prototypes started to be constructed and tested, with the final designed units being completed in October 1982. Originally, the plan was after the first Model 120's were installed, a total of 52 additional Model 120's were going to replace the existing [[Federal Signal]] [[STL-10]]'s and making the system entirely Model 120's. This plan was dropped shortly afterwards due to the increasing delays and costs caused to the plant by not having a ready siren system by 1981 which was the original year planned for the plant's 2 newly constructed reactors to begin operating. Units #2 and #3 were ready to begin operation, but because the siren system was inadequate they couldn't begin operation until the Model 120's were installed. This caused a delay for over a year, as it also happened around the same time the NRC required nuclear plants to have siren systems. This also meant the plant's existing Unit #1 could not be restarted until the siren system was ready.
Originally the plan was after the Model 120s were installed, a now total of 52 sirens were going to be all Model 120s which means swapping out the existing 32 STL-10s with 120s making the system Model 120's only, but this plan was dropped shortly afterwards and only about 8 Model 120s ended up swapping out STL-10s with the other ones being new locations that didn't replace STL-10s. This was due to the whole siren thing causing delays to the plant by not having a ready siren system by 1981 which was the original year for the plants 2 new reactors that just finished construction, Units #2 and #3 to begin operation, but due to the STL-10s originally bought not meeting the plants needs by not effectively covering the EPZ, they had to find another siren that meets the plants needs in order for the plants new reactors to start operations which caused a delay for over a year, this also happened around the same time the NRC required Nuclear plants to have siren systems, but until SONGS get sirens that can perfectly cover the 10 mile EPZ, the plants new reactors could not begin operations, and the plants original reactor that was the first reactor to be built in 1968 (Decommissioned in 1992 and completely demolished by 2006) Unit #1 could not be restarted until the siren system is fully operational and effectively covers the EPZ. So after the Model 120s went up, to end the delays of the siren system not being up to par, which costed over $1 million per day that held up the plant from starting, it was decided to just keep the underperforming STL-10s and just add 21 Model 120s in areas that need coverage to get the EPZ effectiveness up to code for the plants original reactor to restart, and the new reactors to start. After a successful system test around late July 1983, the plants new reactors began operation shortly afterwards with Unit #2 starting on August 8th, 1983, and Unit #3 on April 1st, 1984, as well as Unit #1 restarted.


There were 22 of these sirens produced, with one being never installed and put into storage as a spare. 16 of these were installed in October 1982 to add into the system of STL-10's, 8 of which indirectly swapped out with Model 120's with another 8 being brand new installs. 5 additional sirens were installed in 1988, one of which replaced a [[Federal Signal]] [[Thunderbolt]] that was an existing Civil Defense siren.


For around a decade, they were thought to be "Toshiba" sirens, because they were pneumatic and people just assumed they were made by Toshiba, who also made pneumatic sirens. The Model 120 is a Pneumatic siren, meaning it requires an external air source to produce sound. The sound is chopped by a rotor, which sits inside a hollow cylinder, or stator, which acts as a chamber to contain the air inside. 8 Small narrow slots on the stator allow the sound to come out. The sound is then projected by 8 large fiberglass horns. It consists of a belt driven Paxton blower, that uses a 10 Hp TEFC motor. The rotor is 9.75 inches in diameter and has 5 ports. Including the stator it is in total 11.75 inches in diameter. The rotor is powered by a 2 Hp TEFC motor that spins at 3600 RPM. By 6/10/2004, the plant was discussing a system replacement project due to saying the current system is "aging", and a year later starting In November 2005, (a month after the annual siren test), the Model 120s and the STL-10s started to be gradually removed and replaced, and by Febuary 2006 all have been replaced marking October 26th, 2005 as the final test of the original system, as well as the end of the one of a kind original system that stood out from all other Nuclear plant systems. Whelen WPS 2810s and WPS 2806s were installed in their places. The 2810s went in place of the Model 120s and the 2806s went in place of the STL-10s. These new electronic sirens have battery backup, are more efficient, less maintenance, and having similar ranges to the original system such as the 2806s having better range compared to the STL-10s, and the 2810s having close to the same range but about 2,000 feet less range compared to the the Model 120, but still enough range to cover the EPZ, and as for the strict requirements of the original system, that was no longer an issue as by the 2000s there was commercially produced omnidirectional sirens that have close to the same range as the Model 120 and as well have better range then the STL-10s. After all the old sirens have been removed and replaced, SONGS sold 23 of the STL-10s to Curry County Oregon to be used as tsunami sirens, and the Model 120s and remaining 5 STL-10s are believed to have been scrapped, but its unknown if they were, or went somewhere else but hasn't been discovered. The only Model 120 that is known and remaining is in the possession of Aaron Allevato (Duderocks5539) and Edaan Friedman and currently under restoration to be brought back into operating condition.
After the Model 120's went up, in order to end the delays of the siren system not being up to par, SONGS opted to just keep the remaining [[Federal Signal]] [[STL-10]]'s and add 21 Model 120's in areas that need coverage and to swap out specific STL-10 sites that had the worst range compared to the others, (First 8 sites), to get the EPZ up to code for the plant's reactors to start. After a successful system test on May 4th, 1983, the plant's new reactors began operation shortly afterwards with Unit #2 starting on August 8th, 1983, and Unit #3 on April 1st, 1984, as well as Unit #1 being restarted. These delays, and the cost of the sirens themselves cost the plant over $1 million dollars.




== Other Information ==


[[File:7 Model 120 heads and blowers.jpeg|thumbnail|7 Model 120 heads and Paxton blowers prior to being assembled.]]
For around a decade, they were thought to be "Toshiba" sirens, because they were pneumatic and people just assumed they were made by Toshiba which made pneumatic sirens. The Model 120 is a Supercharged Electromechanical siren, but also more or less acts like a pneumatic siren due to the rotor lacking any vanes, meaning it requires an external air source to produce any meaningful sound, such as the [[Thunderbolt]] and [[Hurricane]]. The sound is created by a 4-port (later 5-port) single tone rotor, which spins inside the stator, which acts as a chamber to contain the air inside. The rotor is driven by a 2 Hp TEFC motor that runs at 3450 RPM. The siren has an 8-port stator with narrow ports, and the sound is then projected by 8 large fiberglass horns attached to the stator. The siren makes use of a belt driven Paxton centrifugal blower, that uses a 10 Hp TEFC motor which sits below the siren's head to force pressurized air up into the rotor. The 4-port units reached a frequency of 240 Hz (480 Hz without the blower) and the 5-port units reached 300 Hz. The rotor and stator are both coated in Teflon, which helps seal the air in and prevent leaks, while also helping to protect them from corrosion from the salty air. The rotor is 9.75 inches in diameter and including the stator, which it alone is over 2 inches in diameter, is in total 11.75 inches in diameter.


[[File:Assembled unit without horns.jpeg|thumbnail|Unit assembled without Horns attached.]]


[[File:Horns being attached and conduits ran to main junction box.jpeg|thumbnail|Horns beginning to be bolted up and conduits from both motors ran to the main junction box for incoming power.]]


[[File:5 out of the 8 horns attached with another unit being assembled off to the left.jpeg|thumbnail|5 out of the 8 horns bolted up with another unit being assembled off to the left. (NOTE: the additional parts on the shelves for units later installed which was another batch of 7 about a few months later).]]
By June of 2004, the plant began discussing a system replacement project due to the sirens suffering from advanced corrosion and degrading reliability due to the system's proximity to the ocean, along with the system "aging", and a year later starting In November 2005, (a month after the annual siren test), the Model 120's and the STL-10's started to be gradually removed and replaced, and by February 2006 all have been replaced marking October 26th, 2005 as the final test of the original system, as well as the end of the one of a kind original system that stood out from all other Nuclear plant systems. [[Whelen Engineering]] [[WPS-2800 series|WPS-2810]]'s and [[WPS-2800 series|WPS-2806]]'s were installed in their places. The 2810's went in place of the Model 120's and the 2806's went in place of the STL-10's.


[[File:Closer view of the head with the siren 95% assembled.jpeg|thumbnail|Closer view of the head with the siren 95% assembled.]]
These new electronic sirens have battery backup, are less maintenance due to their resistance to corrosion and no moving parts, and have similar ranges to the original system such as the 2806's having better range compared to the STL-10's, and the 2810's having close to the same range but about 2,000 feet less range compared to the the Model 120, but still enough range to cover the EPZ. These new sirens met the strict requirements of the plant without the need to specifically design a new siren as by the 2000's, there was commercially produced omnidirectional sirens that have close to the same range as the Model 120 and as well have better range then the STL-10's.


[[File:Fully assembled Model 120.jpeg|thumbnail|Unit after being assembled.]]
After all the old sirens have been removed and replaced, SONGS sold 23 of the STL-10's to Curry County, Oregon to be used as tsunami sirens, 8 of which were installed, and the Model 120's and remaining 5 STL-10's are believed to have been scrapped, but its unknown if they were, or went somewhere else but hasn't been discovered. The only Model 120 that is known and remaining is in private possession currently under restoration to be brought back into operating condition.


[[File:Fully assembled Model 120 with the other 6 being assembled and crated up to be transported to San Onofre Nuclear Generating Station for installation in the 10 mile EPZ around May-June 1983.jpeg|thumbnail|Fully assembled Model 120 with the other 6 being assembled and crated up to be transported to San Onofre Nuclear Generating Station for installation in the 10 mile EPZ. These were the first batch to be installed with another batch of 7 a month or two later, along with a final batch of 7 by 1988 bringing the total number of sirens to 21.]]
== Gallery ==


[[File:99F6BBFC-E550-4A8C-8538-82E2356B663A.jpeg|thumbnail|Rotor and stator of the privately owned unit with a motor attached. As you can see it looks exactly the same as the unit in the photo above, just without the horns and frame assembly. The motor is not the exact same motor as the other ones that were installed, but is the same rating, Horsepower, and RPMs.]]
<gallery mode=packed heights=200px>
7 Model 120 heads and blowers.jpeg|7 Model 120 heads and blowers prior to being assembled.
Assembled unit without horns.jpeg|Assembled unit without horns.
Horns being attached and conduits ran to main junction box.jpeg|Horns being attached and conduits ran to main junction box.
5 out of the 8 horns attached with another unit being assembled off to the left.jpeg|5 out of the 8 horns attached with another unit being assembled off to the left.
Closer view of the head with the siren 95% assembled.jpeg|Closer view of the head with the siren 95% assembled.
Fully assembled Model 120.jpeg|Fully assembled Model 120.
Fully assembled Model 120 with the other 6 being assembled and crated up to be transported to San Onofre Nuclear Generating Station for installation in the 10 mile EPZ around May-June 1983.jpeg|Fully assembled Model 120 with the other 6 being assembled and crated up to be transported to San Onofre Nuclear Generating Station for installation in the 10 mile EPZ in October 1982. These were the first 7 to be installed which replaced 7 STL-10B's.
IMG 7890.jpeg|Siren Location SC-13 illuminated by a spot light at night in 2003. The siren was 21 years old at the time.
99F6BBFC-E550-4A8C-8538-82E2356B663A.jpeg|Head of the privately owned unit with a salvaged motor attached.
</gallery>


== See Also ==
== See Also ==


* Siren patent: https://patents.google.com/patent/US4649853
* Siren patent: https://patents.google.com/patent/US4649853
* Model 120 head run up: https://www.youtube.com/watch?v=mf7YC0Vc_ZI
* Model 120 head dissembled: https://www.youtube.com/watch?v=yOcVk3SrqtY


 
[[Category:Omnidirectional Sirens]][[Category:Electromechanical Sirens]][[Category:Supercharged Sirens]][[Category:Single Toned Sirens]][[Category:SoCal Edison]][[Category:Sirens]]
[[Category:SoCal Edison]][[Category:Omnidirectional Sirens]][[Category:Pnuematic Sirens]][[Category:Single Toned Sirens]][[Category:Sirens]]

Latest revision as of 17:46, 7 April 2024

Model 120
Unit installed on a wood pole
Company Southern California Edison
Produced 1982-1988
Type Electromechanical
Sound output 120 dBc at 100 feet
Frequency 240 or 300 Hz
Horsepower 2 (Rotor) 10 (Blower)

The SoCal Edison (SCE) 120 or Model 120 was a 120 dB low tone supercharged electromechanical siren designed in house by Southern California Edison for use within the 10 Mile Emergency Planning Zone (EPZ) for the San Onofre Nuclear Generating station .

History

The Model 120 was originally created in 1982 as a custom built siren for the SONGS plant, which had strict requirements for its siren system. SONGS had gone through two other systems before this point, with a system of 39 Sentry Siren Incorporated 10V's, 5V's, and 3V8's installed in August 1981 and tested January 25th thru 27th, 1982. The Sentry sirens were found to perform terribly compared to what was advertised, leading to the sirens being removed an replaced. SONGS would then install a new system of 39 Federal Signal STL-10's with those being installed by April of 1982 and tested in May of the same year. While the STL-10's performed significantly better than the Sentry sirens did, they still didn't meet the plant's needs. The only sirens on the market with enough range that would meet the plant's needs at the time were rotational sirens, but SONGS wanted to use exclusively omnidirectional sirens. So, they decided to design and create their own siren to meet their requirements.

Model 120 prototype being mounted to an existing STL-10 pole for range and output testing in Summer 1982.

Starting in around June 1982, Model 120 prototypes started to be constructed and tested, with the final designed units being completed in October 1982. Originally, the plan was after the first Model 120's were installed, a total of 52 additional Model 120's were going to replace the existing Federal Signal STL-10's and making the system entirely Model 120's. This plan was dropped shortly afterwards due to the increasing delays and costs caused to the plant by not having a ready siren system by 1981 which was the original year planned for the plant's 2 newly constructed reactors to begin operating. Units #2 and #3 were ready to begin operation, but because the siren system was inadequate they couldn't begin operation until the Model 120's were installed. This caused a delay for over a year, as it also happened around the same time the NRC required nuclear plants to have siren systems. This also meant the plant's existing Unit #1 could not be restarted until the siren system was ready.

There were 22 of these sirens produced, with one being never installed and put into storage as a spare. 16 of these were installed in October 1982 to add into the system of STL-10's, 8 of which indirectly swapped out with Model 120's with another 8 being brand new installs. 5 additional sirens were installed in 1988, one of which replaced a Federal Signal Thunderbolt that was an existing Civil Defense siren.

After the Model 120's went up, in order to end the delays of the siren system not being up to par, SONGS opted to just keep the remaining Federal Signal STL-10's and add 21 Model 120's in areas that need coverage and to swap out specific STL-10 sites that had the worst range compared to the others, (First 8 sites), to get the EPZ up to code for the plant's reactors to start. After a successful system test on May 4th, 1983, the plant's new reactors began operation shortly afterwards with Unit #2 starting on August 8th, 1983, and Unit #3 on April 1st, 1984, as well as Unit #1 being restarted. These delays, and the cost of the sirens themselves cost the plant over $1 million dollars.


Other Information

For around a decade, they were thought to be "Toshiba" sirens, because they were pneumatic and people just assumed they were made by Toshiba which made pneumatic sirens. The Model 120 is a Supercharged Electromechanical siren, but also more or less acts like a pneumatic siren due to the rotor lacking any vanes, meaning it requires an external air source to produce any meaningful sound, such as the Thunderbolt and Hurricane. The sound is created by a 4-port (later 5-port) single tone rotor, which spins inside the stator, which acts as a chamber to contain the air inside. The rotor is driven by a 2 Hp TEFC motor that runs at 3450 RPM. The siren has an 8-port stator with narrow ports, and the sound is then projected by 8 large fiberglass horns attached to the stator. The siren makes use of a belt driven Paxton centrifugal blower, that uses a 10 Hp TEFC motor which sits below the siren's head to force pressurized air up into the rotor. The 4-port units reached a frequency of 240 Hz (480 Hz without the blower) and the 5-port units reached 300 Hz. The rotor and stator are both coated in Teflon, which helps seal the air in and prevent leaks, while also helping to protect them from corrosion from the salty air. The rotor is 9.75 inches in diameter and including the stator, which it alone is over 2 inches in diameter, is in total 11.75 inches in diameter.


By June of 2004, the plant began discussing a system replacement project due to the sirens suffering from advanced corrosion and degrading reliability due to the system's proximity to the ocean, along with the system "aging", and a year later starting In November 2005, (a month after the annual siren test), the Model 120's and the STL-10's started to be gradually removed and replaced, and by February 2006 all have been replaced marking October 26th, 2005 as the final test of the original system, as well as the end of the one of a kind original system that stood out from all other Nuclear plant systems. Whelen Engineering WPS-2810's and WPS-2806's were installed in their places. The 2810's went in place of the Model 120's and the 2806's went in place of the STL-10's.

These new electronic sirens have battery backup, are less maintenance due to their resistance to corrosion and no moving parts, and have similar ranges to the original system such as the 2806's having better range compared to the STL-10's, and the 2810's having close to the same range but about 2,000 feet less range compared to the the Model 120, but still enough range to cover the EPZ. These new sirens met the strict requirements of the plant without the need to specifically design a new siren as by the 2000's, there was commercially produced omnidirectional sirens that have close to the same range as the Model 120 and as well have better range then the STL-10's.

After all the old sirens have been removed and replaced, SONGS sold 23 of the STL-10's to Curry County, Oregon to be used as tsunami sirens, 8 of which were installed, and the Model 120's and remaining 5 STL-10's are believed to have been scrapped, but its unknown if they were, or went somewhere else but hasn't been discovered. The only Model 120 that is known and remaining is in private possession currently under restoration to be brought back into operating condition.

Gallery

See Also